Studio 5000 Logix Designer V35 enhances process control with Axis Test Mode, expanded SequenceManager for 5x80P controllers, and embedded process instructions. This update, supporting Windows 10/11 and Server 2022, also introduces web-based Add-On Profiles and supports new FLEXHA 5000 I/O. For the full technical details, visit Rockwell Automation PCDC Rockwell Automation Release Note - Rockwell Automation
Virtualization and Process Precision: A Deep Dive into Studio 5000 V35
Rockwell Automation’s Studio 5000 Logix Designer V35 focuses heavily on bridging the gap between physical hardware and digital design. This update introduces features that allow engineers to test motion without motors and manage process sequences with higher granularity. The "No-Motor" Motion Revolution
The standout feature for motion engineers is Axis Test Mode. Traditionally, testing motion profiles required a connected drive and motor, or a complex software emulation setup. V35 allows you to simulate real-time motion behavior at the axis, module, or group level without any physical hardware.
Virtualized Design: It supports physical controllers and emulated ones like FactoryTalk Logix Echo.
Flexibility: You can develop and verify code for Kinetix, PowerFlex, and iTRAK 5730 devices before the machine is even built. Elevating Process Control
For the process industry, V35 marks a major milestone for SequenceManager, expanding support to 5x80P process controllers.
New Native Instructions: Three major process-specific instructions are now embedded directly in the software:
P_SD (Process Discrete Device): Manages multi-state devices (2, 3, or 4 states).
P_nPOS (Process n-Position Device): Controls devices with multiple defined positions.
P_valveMP (Process Mix Proof Valve): Specifically designed to handle the complexities of mix-proof valve feedback and cleaning cycles (CIP/SIP). Modernizing the Interface
Rockwell has begun a visual overhaul of how we configure devices. The Add-On Profiles (AOP) for 5069 and 5094 I/O modules now use a web-based user interface.
Consistency: This provides a common configuration experience across different software platforms.
Important Note: Once you move to this new web-based format for a module, you cannot revert to the old interface style. Efficiency for Power Users
Several "under-the-hood" enhancements target daily productivity: Release Note - Rockwell Automation
Studio 5000 V35 Release Notes
Introduction
The Studio 5000 software suite, part of the Rockwell Automation Integrated Architecture, provides a comprehensive development environment for designing, testing, and deploying industrial automation applications. Studio 5000 V35 is a major release that includes new features, enhancements, and bug fixes. These release notes provide an overview of the changes and updates in this version.
What's New in Studio 5000 V35
The following new features and enhancements are included in Studio 5000 V35:
Enhancements
The following enhancements have been made to existing features in Studio 5000 V35:
Bug Fixes
The following bugs have been fixed in Studio 5000 V35:
Known Issues
The following known issues exist in Studio 5000 V35:
System Requirements
The following system requirements apply to Studio 5000 V35:
Installation Instructions
To install Studio 5000 V35, follow these steps:
Conclusion
Studio 5000 V35 is a comprehensive release that provides new features, enhancements, and bug fixes. These release notes provide an overview of the changes and updates in this version. Refer to the Studio 5000 user manual and online help for more information on using the software. If you have any questions or need assistance, contact Rockwell Automation technical support.
Studio 5000 Logix Designer version 35.00, released in November 2022, focuses on expanding hardware support, including FLEXHA 5000 I/O and the 1756-EN4TR, alongside introducing Axis Test Mode and expanded SequenceManager capabilities. The update also enhances user experience through modernized Add-On Profiles (AOP) and adds official Windows 11 support. For full technical details, visit Rockwell Automation. Release Note - Rockwell Automation Compatibility
Rockwell Automation's Studio 5000 Logix Designer V35 focuses on expanding hardware support for 1756-L8z and GuardLogix 5580 controllers, enhancing motion control for Kinetix 5100 drives, and strengthening CIP security. The update also streamlines workflows with an improved user interface, faster cross-referencing, and updated PlantPAx instructions for the FactoryTalk ecosystem. You can find the release notes and downloads on the Rockwell Automation Product Compatibility & Download Center (PCDC).
Studio 5000 V35 Release Notes
Introduction Rockwell Automation is pleased to announce the general availability of Studio 5000 Logix Designer software version 35. This release focuses heavily on enhancing integration with the Logix platform, improving CIP Security implementations, and expanding the capabilities of specific controller types, such as the ControlLogix 5580 and CompactLogix 5380 controllers.
Key New Features and Enhancements
Resolved Issues This release addresses several customer-reported issues and known anomalies from previous versions. Key fixes include improvements to:
System Requirements To ensure optimal performance, the following minimum system requirements are recommended for Studio 5000 V35:
Installation Instructions Users can install Studio 5000 V35 alongside existing versions of the software, allowing for multi-version support. It is recommended to back up existing project files before opening them in the new version. Please note that once a project is upgraded to version 35, it cannot be reverted to a previous firmware version without restoring from a backup.
Conclusion Studio 5000 V35 represents a continued commitment by Rockwell Automation to provide a secure, reliable, and feature-rich environment for industrial automation. Users are encouraged to review the full technical documentation provided with the installation media for a comprehensive list of all changes and resolved anomalies.
Document Version: 1.0
Intended Audience: Control System Engineers, Automation Managers, OT Cybersecurity Teams
Disclaimer: This paper summarizes official release notes; always consult Rockwell’s latest documentation before production deployment.
Studio 5000 V35, released in late 2022, serves as a significant milestone in Rockwell Automation’s shift toward virtualization and process integration. This version focuses on three pillars: hardware expansion, process efficiency, and digital engineering. Key Feature Enhancements
Axis Test Mode: Perhaps the most notable addition, this feature allows users to simulate motion control (Kinetix, PowerFlex, and iTRAK devices) without physical hardware. This is compatible with both physical controllers and emulated ones via FactoryTalk Logix Echo.
Embedded Process Instructions: Three key instructions previously found in the PlantPAx library are now natively embedded: P_SD: Process Discrete 2-, 3-, or 4-State Device. P_nPOS: Process n-Position Device. P_valveMP: Process Mix Proof Valve.
Logix Designer SDK: V35 introduces the first public scripting utility, allowing developers to use C++ to automate repetitive tasks like opening, saving, and downloading projects.
Expanded SequenceManager Support: Functionality is extended to include 5x80P process controllers, streamlining batch process management.
Modern Add-On Profiles (AOPs): A new web-based user interface for device profiles provides a more modern and responsive configuration experience. System Requirements
V35 is strictly a 64-bit application and does not support 32-bit operating systems. Release Note - Rockwell Automation Compatibility
What’s New in Studio 5000 Logix Designer V35 Rockwell Automation has officially released Studio 5000 Logix Designer V35
, bringing significant productivity boosts to process and motion applications. This update focuses on expanding hardware support and introducing long-requested virtualization features that streamline system design and testing. New Process Instructions & Features
V35 introduces several powerful instructions and features specifically for the process industry:
Embedded Process Instructions: Three new instructions—PD4SD (Process Discrete 2-, 3-, or 4-State Device), PNPOS (Process n-Position Device), and PVLVMP (Process Mix Proof Valve)—are now embedded to align with PlantPAx.
SequenceManager Expansion: Now supports ControlLogix 5580P controllers, allowing process applications to use the same proven sequencing functionality across the latest hardware.
Two-Argument Arctangent (ATAN2): A new math instruction that computes the arc tangent of two sources and returns the result in radians. Motion & Virtualization Highlights Studio 5000 V35 Release Notes
One of the most anticipated features in this release is the ability to test systems without physical hardware:
Axis-Test Mode: You can now virtualize motion for Kinetix, PowerFlex, and iTRAK 5730 CIP Motion devices. This feature supports both physical controllers and emulated controllers via FactoryTalk Logix Echo V2.
User Scripting Utility (SDK): V35 introduces the first publicly available user scripting utility, allowing you to write C++ script commands to automate repetitive tasks within the Logix Designer environment. Expanded Hardware & Compatibility
V35 broadens the scope of supported equipment and improves the user interface:
Supported Hardware: Includes new support for FLEXHA 5000 I/O (extended redundancy), GuardLink, and enhancements for the 1756-EN4TR.
Modern UI for Device Profiles: Add-On Profiles (AOP) now feature a modern web-based interface, providing a common configuration experience across Rockwell's software platforms.
64-bit Data Types: New predefined data types like USINT, UINT, UDINT, ULINT, LINT, and REAL improve precision for 5380, 5480, and 5580 controllers. System Requirements
To ensure optimal performance, your workstation should meet these minimums: Studio 5000 v35 system requirements
Published: October 2023 (Generally Available)
Product Family: Rockwell Automation Studio 5000 (Logix Designer)
Studio 5000 V35 is a security-centric release that prioritizes modern IT/OT convergence at the cost of legacy hardware/OS support. Organizations still on Windows 7 or V32 controllers should plan a migration window. For new greenfield projects requiring CIP Security or high-precision motion, V35 is the recommended baseline. Early adopters should test safety signature workflows and certificate management extensively.
Upgrade immediately if:
Wait for V35.01 if:
Final Verdict: V35 is a mature, performance-driven release with meaningful security upgrades. The resolved anomalies list is impressive, and the known issues have straightforward workarounds. For greenfield projects or regulated industries, V35 is the recommended baseline as of this writing.
Disclaimer: Release notes are accurate as of the general availability date. Rockwell Automation may release minor revisions (35.01, 35.02) that address issues noted above. Always consult Rockwell’s Product Compatibility and Download Center (PCDC) before production deployment.
Here are a few options for a post about "Studio 5000 V35 Release Notes," tailored to different platforms and audiences.
Newly Supported Hardware (Requires FW 35.011):
Discontinued Hardware Support (No longer recognized in V35):