Mitsubishi Tension Controller Le 30 Cta Manual -

Given that this is a discontinued product, here are the legitimate sources (as of 2025):

Caution: Avoid fake "pay-per-download" sites that charge $50 for public-domain manuals. The LE-30CTA manual is copyrighted but freely distributed by Mitsubishi for existing users.


  • I (Integral Time):
  • D (Derivative Time):
  • Filter (FIL):

  • Configure control loop gains:
  • Verify cascade parameters if motor speed is part of loop (tension loop as outer loop, speed/torque inner loop).
  • Test alarms and limit settings (over/under tension, motor torque limits).
  • Run process at low speed and gradually increase while monitoring tension stability.
  • The manual stresses separation of power and signal lines. You must route the sensor cables (shielded twisted pair) away from motor leads. A common mistake documented in the manual’s troubleshooting guide is ground loops—it insists on a single-point ground for the controller. mitsubishi tension controller le 30 cta Manual

    Critical Wiring Table (from manual): | Terminal | Signal | Notes | | :--- | :--- | :--- | | 1, 2 | AC Power | Fuse protection required | | 5, 6, 7 | Tension Sensor (A, B, +EXC) | 5V excitation | | 10, 11 | Analog Output | To brake/clutch | | 14, 15 | External Setpoint | 0-10VDC input |

    | Symptom | Possible Cause | Solution | | :--- | :--- | :--- | | PV Display shows "----" or "OF" | Sensor broken or disconnected | Check wiring to Load Cell (E+/E-). Check for cable breaks. | | Tension does not change | Output fuse blown | Check the fuse protecting the brake/clutch circuit. | | PV is unstable/jittery | Mechanical vibration or noise | Increase the Filter parameter; check for ground loops. | | Output is 100% constantly | Tension too low to detect | Check if load cells are physically working; check Zero calibration. | | Control is slow | PID settings incorrect | Decrease P-Band or Integral time. | Given that this is a discontinued product, here


    Some third-party companies (e.g., Radwell, PLC Center) offer flat-rate repair for the LE-30CTA. Typical failure: capacitor aging in the power supply. Cost: $400-$700.

    After two decades of field service experience, here are unwritten truths about this controller: Caution: Avoid fake "pay-per-download" sites that charge $50


    Unlike modern auto-tuning controllers, the LE-30CTA requires manual PID tuning. The manual provides a starting rule of thumb:

    A dedicated table in the manual matches PID values to material type (e.g., thin film: low P/high I; thick paper: high P/low I).